Publication
Title
Diffusion tensor imaging of the anterior cruciate ligament graft
Author
Abstract
Purpose A great need exists for objective biomarkers to assess graft healing following ACL reconstruction to guide the time of return to sports. The purpose of this study was to evaluate the feasibility and reliability of diffusion tensor imaging (DTI) to delineate the anterior cruciate ligament (ACL) graft and to investigate its diffusion properties using a clinical 3T scanner. Materials and Methods DTI of the knee (b = 0, 400, and 800 s/mm2, 10 diffusion directions, repeated 16 times for a total of 336 diffusion-weighted volumes) was performed at 3T in 17 patients between 3 and 7 months (mean, 4 months) following ACL reconstruction. Tractography was performed by two independent observers to delineate the ACL graft. Fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) were calculated within the graft. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) and the scanrescan reproducibility was evaluated based on the percentage coefficient of variance (%CV) across 20 repetition bootknife samples. Results In all subjects, tractography of the ACL graft was feasible. Quantitative evaluation of the diffusion properties of the ACL graft yielded the following mean ± SD values: FA = 0.23 ± 0.04; MD = 1.30 ± 0.11 × 10−3 mm2/s; AD = 1.61 ± 0.12 × 10−3 mm2/s, and RD = 1.15 ± 0.11 × 10−3 mm2/s. Interrater reliability for the DTI parameters was excellent (ICC = 0.910.98). Mean %CVs for FA, MD, AD, and RD were 4.6%, 3.5%, 3.7%, and 4.4%, respectively. Conclusion We demonstrated the feasibility and reliability of DTI for the visualization and quantitative evaluation of the ACL graft at 3T.
Language
English
Source (journal)
Journal of magnetic resonance imaging. - Chicago, Ill.
Publication
Chicago, Ill. : 2017
ISSN
1053-1807
DOI
10.1002/JMRI.25666
Volume/pages
46 :5 (2017) , p. 1423-1432
ISI
000412894800019
Pubmed ID
28194829
Full text (Publisher's DOI)
Full text (open access)
Full text (publisher's version - intranet only)
UAntwerpen
Faculty/Department
Research group
Project info
Quantitative diffusion tensor imaging of the postoperative anterior cruciate ligament of the knee.
Generalised spherical deconvolution of diffusion MRI data for improved microstructural specificity and higher resolution imaging of white matter.
Publication type
Subject
Affiliation
Publications with a UAntwerp address
External links
Web of Science
Record
Identifier
Creation 16.02.2017
Last edited 04.03.2024
To cite this reference