Publication
Title
Modified bean-shaped ring segments for suture fixation of the bag-in-the-lens intraocular implant
Author
Abstract
We describe a surgical technique for secondary stabilization of a bag-in-the-lens intraocular lens (BIL IOL) using 2 modified bean shaped ring segments in cases of zonular dehiscence associated with pseudophakodonesis. The first modified bean segment is anchored in the sulcus with a suture to the sclera in the area of maximum zonular dehiscence, and the second segment is implanted in the opposite sulcus area. Both segments are placed in the BIL IOL interhaptic groove. The segments stabilize and center the BIL IOL by creating an artificial zonule that provides the necessary extra support for the IOL. (C) 2017 ASCRS and ESCRS
Language
English
Source (journal)
Journal of cataract and refractive surgery. - Fairfax, Va
Publication
Fairfax, Va : 2017
ISSN
0886-3350
DOI
10.1016/J.JCRS.2017.04.042
Volume/pages
43 :8 (2017) , p. 1003-1006
ISI
000411781100003
Pubmed ID
28917396