Title
|
|
|
|
Femoral anteversion measurement : evaluation of inter- and intraobserver reliability
| |
Author
|
|
|
|
| |
Abstract
|
|
|
|
The aim of this study was to evaluate the inter- and intraobserver reliability of a CT-based femoral anteversion measurement. 17 CT scans showing an abnormal anteversion on one side were presented to 6. Three measurements of all scans were obtained : two bilateral measurements and a third measurement with a flipped CT scan. Interobserver correlation results using the spearman test for left, right and anteversion difference had a mean of respectively : 0.918, 0.760 and 0.757. Intraobserver correlation had a maximum of respectively : 0,99, 0,89 and 0,94. Correlation coefficients were consistently higher for the second measurement. The lower correlation boarder of 0,8 was often exceeded. Intraobserver correlation was higher than interobserver correlation. As we evaluated a high variance in interobserver reliability, we recommend an accurate and objective measurement of the anteversion angle. A personal measurement and comparison to the radiological protocol is necessary. |
| |
Language
|
|
|
|
English
| |
Source (journal)
|
|
|
|
Acta orthopaedica Belgica. - Bruxelles, 1946 - 2002
| |
Publication
|
|
|
|
Bruxelles
:
2020
| |
ISSN
|
|
|
|
0001-6462
| |
Volume/pages
|
|
|
|
86
:1
(2020)
, p. 17-21
| |
ISI
|
|
|
|
000538153600003
| |
Pubmed ID
|
|
|
|
32490768
| |
|