Publication
Title
Investigation of using 60 Co source and one detector for determining the flow regime and void fraction in gas–liquid two-phase flows
Author
Abstract
In this study, a simple detection system comprised of one 60Co source and just one NaI detector was investigated in order to identify flow regime and measure void fraction in gas–liquid two phase flows. For this purpose, 3 main flow regimes of two-phase flows including stratified, homogenous and annular with void fractions in the range of 5–95% were simulated by Monte-Carlo N Particle (MCNP) code. At first step, 3 features (count under full energy peaks of 1.173 and 1.333 MeV, and count under Compton continuum) were extracted from registered gamma spectrum. These 3 extracted features were used as inputs of artificial neural network (ANNs). A primary network was trained for identifying the flow regimes, but after testing many different structures, it was found that just two regimes of stratified and annular could be completely identified from each other. After identifying the mentioned two flow regimes by the first ANN, two specific ANNs were also implemented for predicting the void fraction. Using the proposed method in this work, void fraction percentages were predicted with a mean relative error (MRE) of less than only 0.42%. Using fewer detectors is of advantage in industrial nuclear gauges, because of reducing economical expenses and also simplicity of working with these systems.
Language
English
Source (journal)
Flow measurement and instrumentation. - Guildford
Publication
Guildford : 2016
ISSN
0955-5986
DOI
10.1016/J.FLOWMEASINST.2016.06.013
Volume/pages
50 (2016) , p. 73-79
ISI
000383826800008
Full text (Publisher's DOI)
Full text (publisher's version - intranet only)
UAntwerpen
Publication type
Subject
External links
Web of Science
Record
Identifier
Creation 30.10.2020
Last edited 24.08.2024
To cite this reference