Abstract
Purpose Adjoint image warping is an important tool to solve image reconstruction problems that warp the unknown image in the forward model. This includes four-dimensional computed tomography (4D-CT) models in which images are compared against recorded projection images of various time frames using image warping as a model of the motion. The inversion of these models requires the adjoint of image warping, which up to now has been substituted by approximations. We introduce an efficient implementation of the exact adjoints of multivariate spline based image warping, and compare it against previously used alternatives. Methods Using symbolic computer algebra, we computed a list of 64 polynomials that allow us to compute a matrix representation of trivariate cubic image warping. By combining an on-the-fly computation of this matrix with a parallelized implementation of columnwise matrix multiplication, we obtained an efficient, low memory implementation of the adjoint action of 3D cubic image warping. We used this operator in the solution of a previously proposed 4D-CT reconstruction model in which the image of a single subscan was compared against projection data of multiple subscans by warping and then projecting the image. We compared the properties of our exact adjoint with those of approximate adjoints by warping along inverted motion. Results Our method requires halve the memory to store motion between subscans, compared to methods that need to compute and store an approximate inverse of the motion. It also avoids the computation time to invert the motion and the tunable parameter of the number of iterations used to perform this inversion. Yet, a similar and often better reconstruction quality was obtained in comparison with these more expensive methods, especially when the motion is large. When compared against a simpler method that is similar to ours in computational demands, our method achieves a higher reconstruction quality in general. Conclusions Our implementation of the exact adjoint of cubic image warping improves efficiency and provides accurate reconstructions.
Language
English
Source (journal)
Medical physics. - New York, N.Y.
Publication
New York, N.Y. : 2021
ISSN
0094-2405 [print]
2473-4209 [online]
DOI
10.1002/MP.14765
Volume/pages
48 :10 (2021) , p. 6362-6374
ISI
000685750200001
Pubmed ID
34407210
Full text (Publisher's DOI)
Full text (open access)
UAntwerpen
Faculty/Department
Research group
Project info
Novel methods and 4D-XCT tools for in situ characterisation of materials and their microstructural changes during functional testing.
Publication type
Subject
Affiliation
Publications with a UAntwerp address
External links
Web of Science
Record
Identifier
Creation 30.08.2021
Last edited 02.10.2024
To cite this reference