Publication
Title
Methylparaben quantification via electrochemical sensor based on reduced graphene oxide decorated with ruthenium nanoparticles
Author
Abstract
MePa quantification was performed through an electroanalytical method, in which the presence of rGO/RuNPs on GCE surface allowed the increase of the charge transfer rate in the oxidation process of the target molecule. The characterization of the composite material was carried out by TEM, in which the presence of RuNPs with an average diameter of 3.1 +/- 0.5 nm dispersed on the surface of rGO was observed. The electroanalytical method developed showed a linear response range of 5.00 x 10(-7)-3.00 x 10(-6) mol L-1 and LOD of 2.40 x 10(-7) mol L-1. The results were statistically compared with the data obtained by the official method (HPLC) and shown to be equivalent, which allows discussion upon the use of electroanalytical methods of alternative forms of official analysis methods in cosmetic samples. (C) 2017 Elsevier B. V. All rights reserved.
Language
English
Source (journal)
Sensors and actuators : B : chemical. - Lausanne
Publication
Lausanne : 2017
ISSN
0925-4005
DOI
10.1016/J.SNB.2017.05.083
Volume/pages
251 (2017) , p. 739-745
ISI
000406184600090
Full text (Publisher's DOI)