Abstract
Background Percutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal malignancies is unknown. Methods Retrospective analysis of 299 patients undergoing PEG tube placement between January 2006 and December 2008 revealed 57 oncology patients. All patients with head/neck or oesophageal malignancy were treated with chemo- and radiotherapy. In case of high-grade stenosis introducer Freka® Pexact PEG tube was placed (n = 24) and in all other patients (n = 33) conventional pull-type PEG tube. Short-term complications and mortality rates were compared. Results Patients' characteristics and clinical status were comparable in both groups. Short-term complications were encountered in 11/24 (48%) introducer PEG patients as compared to only 4/33 (12%) pull-type PEG patients (P < 0.05). Accidental removal of the introducer PEG tube occurred in 4/24 (17%) with need for surgical intervention in 1 vs. 0/33 (0%, P < 0.05). Wound infection occurred in 3/24 (12%) leading to septic shock and admission to intensive care unit (ICU) in 1 vs. 3/33 (9%, NS). Finally, 3/24 gastrointestinal perforations (12%) resulted from a difficult placement procedure vs. 1/33 (3%), leading to urgent surgical intervention and admission to ICU. Two introducer PEG patients died at ICU, resulting in an overall mortality rate of 8% vs. 0% (P = 0.091). Conclusion The introducer Freka® Pexact PEG procedure for long-term tube feeding may lead to significantly higher complication and mortality rates in patients with head/neck or oesophageal malignancies treated with chemo- and radiotherapy. It is suggested to use the conventional pull-type PEG tube placement in this group of patients, if possible.
Full text (open access)
https://repository.uantwerpen.be/docman/irua/7d13e6/43554a0a.pdf
E-info
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000288987500001&DestLinkType=RelatedRecords&DestApp=ALL_WOS&UsrCustomerID=ef845e08c439e550330acc77c7d2d848
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000288987500001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=ef845e08c439e550330acc77c7d2d848
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000288987500001&DestLinkType=CitingArticles&DestApp=ALL_WOS&UsrCustomerID=ef845e08c439e550330acc77c7d2d848
Handle